MIL-DTL-44312C
TABLE I. End item visual defects (cont'd)
Classification
Examine
Defect
Major
Minor
Hose Assemblies
Distance between reinforcement more or
less than specified:
By 1/8 inch
215
By 1/4 inch
121
Eyelets:
One or more missing or not securely
122
attached through fabric and small air
distribution hose.
Deviating in position from required angle
123
to the extent that intended function
will be seriously impaired or not
performed.
NOTE: This defect should be observed with the hose manifold assembly removed from the vest.
The front and the rear manifolds shall be held firmly together face to face or back to
back. The ends of small hoses shall be parallel and adjacent where affixed to
manifolds. With no force being applied to the hoses, the loop between the front and
back manifolds shall not be skewed in any direction beyond the outside edge of the
front manifold.
Hose assemblies not a tight fit to
124
manifolds(i.e., tunnels, creases, or
puckers in bonded area)
Any insecure bond of hose assemblies to
125
manifolds
Heat shrinkable sleeving:
Not securely affixed.
216
Not fully covering raw edge of cloth
217
Thread ends
Any length extending beyond heat
126
shrinkable sleeving
More than 1/2 inch in length
127
1/4 to 1/2 inch in length
218
Cleanness
Any spot or stain
219
Labels
Omitted, incorrect, illegible, not as
220
Identification and
specified, or not positioned as
instruction
specified.