MIL-DTL-44312C
TABLE II. End item dimensional defects (con't)
Classification
Examine
Defect
Major
Minor
Eyelet vents
Not positioned from edge of sleeve as specified:
More than 1/8 inch
105
Up to 1/8 inch
205
4.4.5 Packaging examination. The fully packaged end items shall be examined for the defects
listed below. The lot size shall be expressed in units of shipping containers. The sample unit
shall be one shipping container fully packaged. The inspection level shall be S-2 and the AQL,
expressed in terms of defects per hundred units, shall be 2.5.
Examine
Defect
Marking (exterior and interior)
Omitted; incorrect; illegible; of improper size, location,
sequence, or method of application.
Materials
Any component missing, damaged, or not as specified.
Workmanship
Inadequate application of components, such as
incomplete sealing or closure of flap, improper
taping, loose strapping, or inadequate stapling.
Bulged or distorted container
Content
Number of vests per container is more or less than
required
Number of vests per unit pack is more or less than
specified
4.4.6
Palletization examination. The fully packaged and palletized end items shall be
examined for the defects listed below. The lot size shall be expressed in units of
palletized unit loads. The sample unit shall be one palletized unit load, fully packaged.
The inspection level shall be S-1i and the AQL, expressed in terms of defects per hundred
units, shall be 4.0.